Download Waste Water Case Studies

 

Case Studies are available to download below, just click on the documents you are looking for.

It will open the pdf in your browser so you can save it to your computer as required.

Alternatively we are more than happy to help directly, just phone us or email info@haigh.co.uk

Site NameFlow Rates (l/s)Download
Notes
BakewellNormal

Storm
1501500 Duty/Standby ACE Inlet
SharpnessNormal

Storm
16

140
1000 Duty/Standby ACE Package
Bunch of CarrotsA 202 Pipeliner and Progressive Cavity Pump
Praze An BeebleNormal

Storm
25

79
A 991 ACE Screener in a prefabricated Inlet with the Lipactor Station sited approximately 20 metres away adjacent to the existing roadway.
GoonhavernNormal

Storm
3.5

10
A channel mounted 591 ACE Screener with screenings disposal via a Carriskip
Week St MaryNormal

Storm
11.2A channel mounted 490 ACE Screener feeding to a remote Lipactor Station discharging into a skip
StarcrossNormal

Storm
55A 741 ACE Screener mounted in a prefabricated inlet with an ACE Gritter and Lipactor Station mounted on a small access platform
DinasNormal

Storm
10

40
A 740 ACE Screener mounted in a prefabricated inlet with a Storm Overflow box on the downstream side
AbbotsburyNormal

Storm
3

9
A 590 ACE Screener mounted in a prefabricated inlet
BroadmayneNormal

Storm
10A 590 ACE Screener, Lipactor Station and Control Panel mounted on an existing Gantry with screenings discharge into a skip at ground level
Stourton CaundleNormal

Storm
12A 490 ACE Screener mounted in a prefabricated inlet with the Lipactor Station approximately 15 metres away
NetheravonNormal

Storm
4

60
A 991 ACE Screener mounted in an existing concrete channel which was modified to suit. The Screener and Pump are fitted with ATEX motors as they are below coping level
SherstonNormal

Storm
40A 591 ACE Screener mounted in an existing channel with Lipactor Station mounted adjacent on a concrete plinth
FerniegairNormal

Storm
50A 591 ACE Screener mounted in a prefabricated inlet together with an ACE Gritter mounted on a grit inlet box on the upstream of the Screener
MardenNormal

Storm
20A 590 ACE Screener, Lipactor Station and Control Panel mounted on a bespoke stainless steel gantry, pre-piped and pre-wired for installation in a single lift.
Patricks Tankered Waste20An ACE Sludge Screener mounted in a prefabricated inlet with a simple pipe in / pipe out modular design together with a Lipactor Station and Control Panel
Roxwell STWPumped6A 490 ACE Screener mounted in a prefabricated inlet complete with a 152 Ace Pump, LS305-4VR Lipactor Station with extended discharge chute and a Touch Screen Control Panel all mounted on a raised GMS Platform.
Hermon STWNormal

Storm
1.22

30
A 591 Ace Screener mounted in a prefabricated inlet box complete with 302 Ace Pump, LS305-4VR Lipactor Station and Touch Screen Control Panel
East BergholtNormal

Storm
6

52
A 741 ACE Screener mounted in a prefabricated inlet feeding to a Lipactor Station on a raised plinth.
SwinderbyNormal

Storm
30

85
A 991 ACE Screener, Lipactor Station and Control Panel mounted on a bespoke galvanised mild steel gantry with screenings discharge to a wheelie bin at ground level
Castle AshbyA 490 ACE Screener mounted in a prefabricated inlet complete with inlet box, handrake screen, Series 2 152 Ace Pump, LS305-4VR Lipactor Station and Touch Screen Control Panel
CarnoNormal1.12 A 491 ACE Screener mounted in a prefabricated inlet with the Lipactor Station and Control Panel mounted directly onto the inlet to form a single pre-piped and pre-wired unit for installation.

 