Download ACE Screener and ACE Inlet Block Drawings

 

ACE Screener and Prefabricated ACE Inlet Block Drawings

Click on the links below to download .dxf or .pdf format block drawings of the popular ACE Screener units for your site design.

An ACE Screener system comprises of an ACE Screen unit, Lisep dewatering station and a control panel that can be configured for maximum site layout flexibility from standardised modules.

An ACE Inlet in a prefabricated channel removes the need for concrete channels, concerns about site hydraulics, incorporating an overflow hand-rake screen and has the potential for either manual or automated Grit Removal

Screen parameters (e.g. perforation size 2mm, 3mm, 5mm, 6mm) can be specified independently, flow rates based on 6mm 2D screening, raw sewage. Applications with non-standard solids loading, capacities may vary.

Where applicable, left hand and right hand versions are available, with the Manual access / control panel being sited on that side when viewed in the direction of flow.

Screening capture ratio is 64%@6mm 2D as tested at NSEF Chester le Street unless otherwise specified.

Unit.dwgMax l/sp.e.Wgt / kgNotes
290 ACE Screener
104591-01.zip
15500Screen unit - for fitting into existing concrete channel

Lisep Station / Control Panel should be mounted on the side of the concrete channel or at another convenient location.
490 ACE Screener
104592-01.zip
301000
590 ACE Screener
104593-01.zip
402000
740 ACE Screener
103668-01.zip
503500
491 ACE Screener
[DWG]
453000
591 ACE Screener
[DWG]
605000
741 ACE Screener
[DWG]
757500
991 ACE Screener
[DWG]
10010000
LS305 Lisep
T106367-01.zip
T106367-02.zip
T106367-03.zip
T106367-04.zip
T106367-05.zip
T106367-06.zip
T106367-01 - With Combined Stand - Carriskip (Panel Posn - 3 Options)
T106367-02 - With Combined Stand - Wheelie Bin (Panel Posn - 3 Options)
T106367-03 - With Combined Stand - Skip (Panel Posn - 3 Options)
T106367-04 - With Stand - Carriskip.
T106367-05 - With Stand - Wheelie Bin.
T106367-06 - With Stand - Skip.
490 ACE Inlet
L:[DWG]
R:[DWG]
301000Complete Combined Screen & Screenings Handling Inlet unit

Pipe-in, Pipe out applications, incorporates Handrake 1D screen as standby.

Lisep station either Integrated onto Inlet or remote - does not alter footprint of unit.

Grit removal can be automated - shown as manual version
590 ACE Inlet
L:[DWG]
R:[DWG]
402000
740 ACE Inlet
L:[DWG]
R:[DWG]
503500
491 ACE Inlet
L:[DWG]
R:[DWG]
453000
591 ACE Inlet
L:[DWG]
R:[DWG]
605000
741 ACE Inlet
L:[DWG]
R:[DWG]
757500
991 ACE Inlet
L:[DWG]
R:[DWG]
10010000
Twin 490 Inlet
L:[DWG]
R:[DWG]
301000Complete Combined Screen & Screenings Handling

Pipe-in, Pipe out applications, incorporates Handrake 1D screen.

Lisep station either Integrated onto Inlet or remote - does not alter footprint of unit.

Grit removal can be automated - shown as manual version

Duty Standby / Duty Assist configuration
Twin 590 Inlet
L:[DWG]
R:[DWG]
402000
Twin 740 Inlet
L:[DWG]
R:[DWG]
503500
Twin 491 Inlet
L:[DWG]
R:[DWG]
453000
Twin 591 Inlet
L:[DWG]
R:[DWG]
605000
Twin 741 Inlet
L:[DWG]
R:[DWG]
757500
Twin 991 Inlet
L:[DWG]
R:[DWG]
10010000
While these drawings are stable production versions they are UNCONTROLLED - please contact us if required to confirm that you have the most suitable version

Flow rate converter from litres per second (lps or l/s) to MegaGallons per day (MGD)

 